آویژه هامون

ARAD - AHIT Rack AIR DISTRIBUTION

ویژگی های ARAD - AHIT Rack AIR DISTRIBUTION

In large data centers whose cold air distribution system uses Down Flow technology, due to the obstacles and oppositions created under the false floor, such as cable trays and data distribution cables, as well as improper air outlets from cold wind transmission tiles, proper distribution is possible. The generated cold is not possible and usually, 20 to 40% of the cold air produced under the site floor is lost and is useless. Therefore, the need for equipment that can deliver the cold air produced from under the false floor to the equipment inside the rack is very useful and necessary.

  • Small size to minimize space occupied in the rack (2U)
  • Two power input connectors for power supply (Dual Power) from two separate panels
  • Ability to change the power input automatically in case of interruption of any of the inputs
  • Ability to throw cold air to the highest unit in racks
  • Has a filter to prevent dust from entering the cabinet
  • Ability to replace the filter in a sliding manner without the need to open the equipment
  • Possibility of installation on all racks in the market, due to the sliding air outlet

بررسی اجمالی محصول

The air distribution device inside the rack is closed in the lowest unit of the rack and its task is to transfer cold air directly from the floor of the site to the highest point of the rack. This device is used in data centers that use Down Flow technology to distribute cooling. This device is used to minimize the temperature gap between the bottom and top of the rack and helps maintain the proper air temperature in the rack by improving the airflow rate.

                           

The air distribution device inside the rack is closed in the lowest unit of the rack and its task is to transfer cold air directly from the floor of the site to the highest point of the rack. This device is used in data centers that use Down Flow technology to distribute cooling. This device is used to minimize the temperature gap between the bottom and top of the rack and helps maintain the proper air temperature in the rack by improving the airflow rate


                
Due to the sliding wind throw section, it can be installed in all racks. This device is useful for racks higher than 1.5 kW, up to 4 kW, this device is designed to effectively throw cold air to the highest equipment installed in the rack and bring the inlet temperature of the equipment to the minimum defined in the standard. The innovative design of this device allows quick and easy installation


 Technical specifications 

Power distribution system specifications

220V, 230V

Nominal Input Voltage

50/60 Hz

Input frequency

C-13

Input Connections

2

Number of Power Cords

26 Watts 

Input Power



 
Physical specifications

90MM

Maximum Height

422MM

Maximum Width

590MM

Maximum Depth

2U

Rack Height

15KG

Net Weight

170 m³/h

Air Volume

50dB

Audible noise at 1 meter from surface of unit














Components
This device consists of 6 pieces that are finally assembled and placed inside the box
The main body of the device
Device fan
Filter drawer of the device which is located under the body
Filter
(Device installation kit (side rails
(Two interface cables (Power Cord